CHNXM - AC 4047528 8OZ LEAK DETECTOR, 039360

  • MSDS: CHNXM
  • Manufacturer: WILLIAM H HARVEY CO
  • Product Name: AC 4047528 8OZ LEAK DETECTOR, 039360
  • National Stock Number: 6850-00N088124
Product Identification

Product ID:AC 4047528 8OZ LEAK DETECTOR, 039360
MSDS Date:04/24/1995
FSC:6850
NIIN:00N088124
MSDS Number: CHNXM

Responsible Party
WILLIAM H HARVEY CO
4334 SOUGH 67TH ST
OMAHA, NE 68117-1019
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 800-228-9681

Cage: IO530

Contractor
WILLIAM H HARVEY CO
OMINA, NE 68131 US

Telephone: 402-553-0479

Cage: IO530

Ingredients

NON-HAZARDOUS INGREDIENTS

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE & CHRONIC: NONE INDICATED. SIGNS
& SYMPTOMS OF EXPOS: EYES: THIS MATL MAY CAUSE EYE IRRIT. SKIN:
SLIGHT REDNESS MAY DEVELOP ON HANDS OR FOREARMS IF INDIVIDUAL HAS A
HISTORY OF DERMAL ALLERGIC RE ACTION. DERMATITIS & SKIN SENSIT CAN
DEVELOP AFTER RPTD &/OR PRLNGD CONTACT W/HUMAN SKIN. SKIN (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ABSORPTION: SYSTEMICALLY TOXIC CONCS
WILL PROBABLY NOT BE ABSORBED THRU THE SKIN IN HUMANS. INHAL: NONE
KNOWN. INGEST: NO EFT IF INGESTED IN SMALL AMTS. RELATIVE TO OTHER
MATLS A SINGLE DOSE OF THIS PROD IS RARELY TOXIC BY INGESTION.
NUMBNESS OF MOUTH &/OR IRRIT OF STOMACH CAN DEVELOP FOLLOWING
INGESTION.
Medical Cond Aggravated by Exposure:NONE INDICATED.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
OXYGEN/ARTIFICIAL RESPIRATION) . EMER FIRST AID CALL:
1-303-623-5716 COLLECT. EYES: FLUSH IMMEDIATELY WITH WATER FOR AT
LEAST 15 MINUTES. IF I RRIT PERSISTS HAVE EYES EXAMINED & TREATED
BY MED PERS. SKIN: IF IRRIT OCCURS REMOVE CONTAM CLTHG & FOOTWEAR.
WASH MATL OFF SKIN W/PLENTY OF SOAP & WATER. WASH CLTHG & FOOTWEAR
BEFORE REUSE. (SUPDAT)

Fire Fighting

Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL POWDER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE INDICATED.

Accidental Release

Spill Release Procedures:WHERE POSSIBLE FLUSH DOWN DRAIN TO WASTE
TREATMENT SEWER; OTHERWISE ON SMALL SPILLS, USE CHEMICAL ABOSRBENT
AND SWEEP UP. FOR LARGE SPILLS, CONTAIN AND COLLECT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NORMAL ROOM VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . OTHER
PROT EQUIP AS DETERMINED BY/RECOMMENDED BY FED, STATE OR LOCAL
REGS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: INGEST: DRINK WATER OR MILK TO DILUTE. INDUCE VOMITING
ONLY IF ADVISED BY MD OR POISON CONTROL CENTER. CALL POISON CONTROL
CENTER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:WATER
Vapor Density:WATER
Spec Gravity:1.0 (H*2O=1)
Evaporation Rate & Reference:WATER
Solubility in Water:INFINITE
Appearance and Odor:CLEAR, LIGHT BLUE LIQUID; ALMOST ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE INDICATED.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE INDICATED.

Disposal

Waste Disposal Methods:DISPOSE OF THIS PRODUCT OR ITS RESIDUES IN
ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REQUIREMENTS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.